YCX8-(Fe) Photovoltaic DC Combiner Box
Features ● The box can be made of hot-dip galvanized steel plate or cold-rolled steel plate to ensure that the components do not shake and remain unchanged in shape after installation and operation; ● Protection grade: IP65; ● Can simultaneously access up to 50 solar photovoltaic arrays, with a maximum output current of 800A; ● The positive and negative electrodes of each battery string are equipped with photovoltaic dedicated fuses; ● The current measurement adopts Hall sensor perforated mea...PvT Series
Features Makes photovoltaic power generation safer Quick connection of photovoltaic cables and easy to install Extremely low contact resistance Waterproof and dustproof design Excellent resistance to high and low temperatures, fire, and UV radiation Selection PvT — P DC1500 Model Installationcategory Rated current Rated voltage Photovoltaic Special Connector /: Plug-inconnection P: Panel installation connection Hard connection: LT2: 1-to-2 LT3: 1-to-3 LT4: 1-to-4 LT5: 1-to-5 LT6: 1...YCX8-DIS Door Clutch Combiner
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-DIS 1/1 15/32 Input/Output 1/1 Maximum voltage 600V 1000V Short circuit current per input (Isc) 15A-30A(Adjustable) Maximum output current 16A 25A Shell frame Material Polycarbonate Protection degree IP66 Impact resistance IK10 Dimension(width ×height ×depth) 160*210*110 Input cable gland MC4/PG09,2.5~16mm Out...YCB1-125 MCB
Curve Specifications Type Standard IEC/EN 60947-2 IEC/EN 60898-1 Electrical features Rated current In A 63, 80, 100, 125 Poles P 1, 2, 3, 4 Rated voltage Ue V 230/400 Insulation voltage Ui V 500 Rated frequency Hz 50/60 Rated breaking capacity A 6000 Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1min kV 2.5 Pollution degree 3 Thermo-magnetic release characteristic 8-12In B, C,D Mechanical features Electrical life t ...YCM8-PV Photovoltaic DC MCCB
Features ● Ultra-wide breaking capacity: rated working voltage up to DC1500V and rated current up to 800A. Under DC1500V working conditions, Icu =Ics=20KA, ensuring reliable short-circuit protection. ● Small size: for frame currents up to 320A, the 2P rated working voltage can reach DC1000V, and for frame currents of 400A and above, the 2P rated working voltage can reach DC1500V. ● Ultra-long arc-extinguishing chamber: the arc-extinguishing chamber has been improved as a whole, with more arc-...RT18 Low Voltage Fuse
Fuse Holder RT18 Type Assorted Fuse Ratedvoltage (V) RatedCurrent (A) Dimension (mm) A B C D E RT18-32(32X) 1P 10 ×38 380 32 82 78 35 63 18 RT18-32(32X) 2P 32 82 78 35 63 36 RT18-32(32X) 3P 32 82 78 35 63 54 RT18-63(63X) 1P 14 ×51 63 106 103 35 80 26 RT18-63(63X) 2P 63 106 103 35 80 52 RT18-63(63X) 3P 63 106 103 35 80 78 RT18L Type Assorted Fuse Number of Poles Rated voltage (V) Conventional heating current (A) Dimension (mm) A B C D E RT18L-63 14 ×51 1,2,3,4 690 6...