YCX8-IF Solar DC Fuse Box
Features ● IP65; ● 3ms arc suppression; ● Lockable in closed position; ● Fuses with overcurrent protection. Technical data Model YCX8-IF III 32/32 Input/Output III Maximum voltage 1000VDC Maximum DC short-circuit current per input (Isc) 15A(Adjustable) Maximum output current 32A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 381*230*110 Configuration (recommended) Photovoltaic isolation switch YCISC...YCX8-BS Over-Load Protection Box
Features ● IP66; ● 1 input 4 output, 600VDC/1000VDC; ● Lockable in closed position; ● UL 508i certificated, Standard: IEC 60947-3 PV2. Technical data Model YCX8-BS 1/1 YCX8-BS 6/2 Input/Output 1/1, 3/1 6/2 Maximum voltage 1000VDC Maximum output current 1~63A/63A~125A Shell frame Material Polycarbonate/ABS Protection degree IP65 Impact resistance IK10 Dimension(width ×height ×depth) 219*200*100mm 381*230*110 Configuration (recommended) Photovoltaic DC circuit breake YCB8...YCX8-T Waterproof Electrical Box
Selection YCX8 — T 858575 Corresponding overall dimensions(mm) Model Box type Dimension A B C D E Plastic distribution box T: Electrical box (transparent cover) 858575 85 85 75 74 74 111180 110 110 80 104 104 131390 130 130 90 124 124 131890 130 180 90 154 154 161690 160 160 90 154 154 162111 160 210 110 154 204 162112 160 210 120 154 204 182511 180 250 110 174 244 182511 180 250 120 174 244 202011 200 200 110 194 194 202012 200 200 120 194 194 212911...YCS8-S Photovoltaic DC Surge Protective Device
Features ● T2/T1+T2 surge protection has two types of protection, which can can meet Class I (10/350 μS waveform) and Class II (8/20 μS waveform) SPD test, and voltage protection level Up ≤ 1.5kV; ● Modular, large-capacity SPD, maximum discharge current Imax=40kA; ● Pluggable module; ● Based on zinc oxide technology, it has no power frequency aftercurrent and fast response speed, up to 25ns; ● The green window indicates normal, and the red indicates a defect, and the module needs to be replac...YCB1-125 MCB
Curve Specifications Type Standard IEC/EN 60947-2 IEC/EN 60898-1 Electrical features Rated current In A 63, 80, 100, 125 Poles P 1, 2, 3, 4 Rated voltage Ue V 230/400 Insulation voltage Ui V 500 Rated frequency Hz 50/60 Rated breaking capacity A 6000 Rated impulse withstand voltage(1.2/50) Uimp V 6000 Dielectric test voltage at ind. Freq. for 1min kV 2.5 Pollution degree 3 Thermo-magnetic release characteristic 8-12In B, C,D Mechanical features Electrical life t ...YCISC8-32 Photovoltaic DC Isolation Switch
Features ● E type external installation can reach IP66 waterproof level at any angle; ● UV resistant and V0 flame retardant material; ● Contact silver plating, silver layer thickness reaches the highest standard in the industry; ● Arc extinguishing time(3ms); ● The bottom of the external box is equipped with a breather valve; ● Nonpolarity; ● Lockable in closed position; ● 4 installation modes optional. Selection YCISC8 — 32 X PV P 2 MC4 13A + YCISC8-C Model Rated current With lock or n...